Do windows in removable casts increase local pressure?

Isabelle Dumont

This article details a trial carried out to establish whether using an offloading cast with a window to treat diabetic neuroischaemic ulcers caused high pressure around the window and whether this pressure, known as the edge effect, carried the risk of developing a new ulcer. The study involved the participation of nine people who received offloading treatment via a cast known as the Ransart boot, which is small, removable, and windowed. The study showed that high peak pressure did not occur around the windows. The author concluded that it was safe to cut a window in this type of cast.

It is accepted that abnormal forces applied to the skin play a key role in the pathogenesis of the majority of ulcers on both the side and the plantar aspect of the diabetic foot, and that these include both direct pressure and shearing forces (Masson et al, 1988). Once an ulcer occurs, it is important to minimise these forces; offloading techniques are an essential part of the routine management of ulcers on the sole and the side of the foot (Caravaggi et al, 2000; Armstrong et al, 2001; Boulton and Armstrong, 2003; Bus et al, 2008). A variety of removable and nonremovable devices have been developed (Katz et al, 2005; Piaggesi et al, 2007), each with its advantages and disadvantages. 

The use of casts with a window cut under the ulcer are very seldom mentioned in this field. The Scotch cast boot (Burden et al, 1983), as well as the Ransart boot – developed by the author (Dumont et al, 2009) – are the only casts of this kind that are described and studied. Making a window in a cast is generally advised against, due to the so-called “edge effect” (Armstrong and Athanasiou, 1998), in which the window borders are thought to apply high pressure, thus carrying the risk of a new ulcer developing. As no study has ever been published assessing the “edge effect”, although in a number of studies involving the use of windowed casts, no lesion around the windows has been noticed (Burden et al, 1983; Borssén and Lithner, 1989; Ha Van et al, 2003). Moreover, no real pressure threshold has been defined to establish at which point the risk of developing an ulcer would be greater.

The author undertook this trial to determine whether making a window in a cast increased the risk of lesion around the window.

Materials and methods
This study was conducted in the author’s centre where the Ransart boot (Figure 1) is the standard offloading cast used. Patients were included if they had an active ulcer on the plantar aspect of the foot, were aged between 18–85 years, had type 1 or type 2 diabetes, and diabetic peripheral neuropathy (defined as vibration perception threshold ≥25 V tested on the hallux by using a biothesiometer [Horwell], or insensitivity to a 10-g monofilament tested at a number of sites on the plantar surface of the foot). Ischaemic patients were not excluded. Patients with active Charcot disease were excluded.

Ulcers were classified according to the University of Texas system (Armstrong et al, 1998a). Depth was judged by inspection and, when appropriate, probing after debridement. Peripheral arterial disease was assessed by the palpation of pedal pulses. Guidelines published by the Infectious Diseases Society of America (Lipsky et al, 2004) were used to determine the presence of infection. Active infection was not a criterion for exclusion. 

Ransart boot
It takes approximately 30 minutes to make a Ransart boot (Dumont et al, 2009). First, the ulcer is covered with a simple protective dressing. A synthetic stocking is placed over the foot and lower leg, which is then encased in a roll of soft cast casting tape. The sole of the boot is reinforced with Scotchcast™ (3M) before applying a roll of Scotchcast™ Soft Cast Casting Tape (3M). The cast is moulded to the foot, with no special protection applied to bony prominences. The cast is left open just below the malleoli and a window is cut out over the ulcerated area as close to the ulcer edges as possible. The edges of the windows are abrupt. The cast is shaped to make easier to remove and is secured with Velcro®

Ulcer management
Aside from the use of a Ransart boot, ulcers of all participants were managed according to the principles of the International Consensus on the Diabetic Foot (Bakker et al, 2011). Debridement of the wound was performed once a week.

The F-scan
The F-Scan® (Tekscan®) insole pressure assessment system, which has been described elsewhere (Young, 1993), was used to measure plantar foot pressures. The F-Scan pressure insoles were calibrated for each patient according to the manufacturer’s specifications and all tests were carried out by the same operator. The procedure was standardised at the beginning of the study using healthy controls. 

Before testing, the patients walked for several minutes in order to become comfortable with the system. Patients were asked to walk at their normal cadence and strike length. Data collection began after the second step and continued for at least eight consecutive steps on the same walkway. There were 5–10 trials for each patient. The peak plantar pressure was recorded in kg/cm² around the windows on the four borders and inside the cast approximately 1 cm away from the window edge, all around the perimeter of the window (Figure 2).

Fifty frames were recorded for each step. At each frame they kept just one value: the highest peak plantar pressure from anywhere within the window border. The same was recorded for the results of the control (represented by the blue border inFigure 2), which is inside the boot 1 cm from, and perpendicular to, the window.

The Student’s t–test was used to compare two sample means. 

Results
The patient demographic data and specific foot histories are shown in Table 1. Nine participants were included in the study (six men, three women; mean age, 59.1 ± 5.7 years). All had type 2 diabetes. This population is representative of those encountered in routine specialist practices in northern Europe and the USA, with the patient characteristics being very similar to those in other series (Oyibo et al, 2001; Jeffcoate et al, 2006).

None of the participants developed a new ulcer in another area of the foot with the reference ulcer, or on the other foot, during the period of the study and no herniation of the wound edges took place. The mean area of the windows was 9.4 ± 1.5 cm2.

The author analysed three steps per patient, with a total of 26 steps for nine patients. Table 2 shows the results of each patient for each recorded step, which were all broadly consistent. The highest level of pressure found around the windows was 6.5 kg/cm², the lowest 1.6 kg/cm², and the mean was 4 ± 1.3 kg/cm². The peak pressure found in the cast 1 cm from the windows was 8.1 kg/cm², the lowest 3.3 kg/cm², and the mean 5.3 ± 1.4 kg/cm². Differences between these values are not statistically different.

Participants with prior Lisfranc or toe amputations were found to have comparable in-cast pressures similar to the other patients, suggesting that when using the Ransart boot the patients’ walking pattern did not differ depending on the shape of the foot. Thus, the location of the ulcer does not impact on the results.  

Discussion
To date, no agreed pressure threshold has been defined above which the risk of developing an ulcer increases. A range of values have been proposed by various authors, including: 

  • 6 kg/cm² (Frykberg et al, 1998)
  • 6.5 kg/cm² (Lavery et al, 1998)
  • 7.1 kg/cm² (Armstrong et al, 1998b).

In the present study, the peak pressure found around the windows was 6.5 kg/cm², a value that sits within those suggested above as placing patients at increased risk of developing an ulcer. The peak pressure in the cast, 1 cm away from the windows, was 8.1 kg/cm², higher than that found around the window. These values are the highest recorded in any of the participants, and it should be noted that they occur only during one frame, so for less than one second. Mueller (1999) states: “The longer time the pressure is applied or the more steps a person takes with a given magnitude of pressure experienced on each footstep, the higher the risk for skin breakdown.”

Interestingly, the mean peak pressure in the present study was 4 ± 1.3 kg/cm² around the windows and 5.3 ± 1.4 kg/cm² in the cast, 1 cm away from the window. These values are in the range of pressures found by different authors in shoes and socks. Donaghue et al (1996) used the F-Scan to measure pressure in different types of shoes worn by people with diabetic peripheral neuropathy and found pressures ranging from 3.98 ± 1.4 to 6.56 ± 2.7 kg/cm². Similarly, Frykberg et al (1998) used the F-Scan to measure pressure in diabetic neuropathic patients wearing socks and the results varied between 4.4 ± 1.9 and 6.7 ± 2.9 kg/cm². Sarnow et al (1994) also used the F-Scan to measured in-shoe foot pressure in people with diabetic peripheral neuropathy wearing shoes or socks; with either shoes or socks alone the highest pressures varied between 5.27 ± 2.39 and 8.77 ± 4.68 kg/cm². 

Conclusion
The author evaluated peak pressures in a small, removable, windowed, offloading cast in nine people with active foot ulceration and diabetic peripheral neuropathy managed in a single centre. The peak pressures around the window were not such that they would risk the patient developing an ulcer. Although a larger study is needed to confirm the findings reported here, these data suggest that using a window in this type of cast is safe in people with active ulceration and diabetic peripheral neuropathy.

Acknowledgments
The author wishes to thank Johan Poitier for his technical assistance.

REFERENCES:

Armstrong DG, Athanasiou KA (1998) The edge effect: how and why wounds grow in size and depth. Clin Podiatr Med Surg 15: 105–8
Armstrong DG, Lavery LA, Harkless LB (1998a) Validation of a diabetic wound classification system. The contribution of depth, infection and ischemia to risk of amputation. Diabetes Care 21: 855–9
Armstrong DG, Peters EJ, Athanasiou KA et al (1998b) Is there a critical level of plantar foot pressure to identify patients at risk for neuropathic foot ulceration? J Foot Ankle Surg 37: 303–7
Armstrong DG, Nguyen HC, Lavery LA et al (2001) Off-loading the diabetic foot wound: a randomized clinical trial. Diabetes Care 24: 1019–22
Bakker K, Apelqvist J, Schaper NC, International Working Group on Diabetic Foot Editorial Board (2011) Practical guidelines on the management and prevention of the diabetic foot 2011. Diabetes Metab Res Rev 28(Suppl 1): 225–31
Borssén B, Lithner F (1989) Plaster casts in the management of advanced ischemic and neuropathic diabetic foot lesions.Diabet Med 6: 720–3
Boulton AJ, Armstrong DG (2003) Trials in neuropathic diabetic foot ulceration: time for a paradigm shift? Diabetes Care 26: 2689–90
Burden AC, Jones GR, Jones R et al (1983) Use of the “Scotchcast boot” in treating diabetic foot ulcers. BMJ 286: 1555–7
Bus SA, Valk GD, van Deursen RW et al (2008) The effectiveness of footwear and offloading interventions to prevent and heal foot ulcers and reduce plantar pressure in diabetes: a systematic review. Diabetes Metab Res Rev 24: 162–80
Caravaggi C, Faglia E, De Giglio R el al (2000) Effectiveness and safety of a nonremovable fiberglass off-bearing cast versus a therapeutic shoe in the treatment of neuropathic foot ulcers: a randomized study. Diabetes Care 23: 1746–51
Donaghue VM, Sarnow MR, Giurini JM et al (1996) Longitudinal in-shoe pressure relief achieved by specially designed footwear in high risk diabetic patients. Diabetes Res Clin Pract 31: 109–14
Dumont IJ, Lepeut MS, Tsirtsikolou DM et al (2009) A proof-of-concept study of the effectiveness of a removable device for offloading in patients with neuropathic ulceration of the foot: the Ransart boot. Diabet Med 26: 778–82
Frykberg RG, Lavery LA, Pham H et al (1998) Role of neuropathy and high foot pressures in diabetic foot ulceration. Diabetes Care 21: 1714–9
Ha Van G, Siney H, Hartmann-Heurtier A et al (2003) Nonremovable, windowed, fiberglass cast boot in the treatment of diabetic foot ulcers. Diabetes Care 26: 2848–52
Jeffcoate WJ, Chipchase SY, Ince P et al (2006) Assessing the outcome of the management of diabetic foot ulcers using ulcer-related and person-related measures. Diabetes Care 29: 1784–7
Katz IA, Harlan A, Miranda-Palmer B et al (2005) A randomized trial of two irremovable off-loading devices in the management of plantar neuropathic diabetic foot ulcers. Diabetes Care 28: 555–9
Lavery LA, Armstrong DG, Vela SA et al (1998) Practical criteria for screening patients at high risk for diabetic foot ulceration. Arch Intern Med 158: 157–62
Lipsky BA, Berendt AR, Deery HG et al (2004) Diagnosis and treatment of diabetic foot infections. Clin Inf Dis 39: 885–910
Masson EA, Hay EM, Stockley I et al (1988) Abnormal foot pressures alone may not cause ulceration. Diabetic Med 6: 426–8
Mueller MJ (1999) Application of plantar pressure assessment in footwear and insert design. J Orthop Sports Phys Ther 29: 747–55
Oyibo SO, Jude EB, Tarawneh I et al (2001) A comparison of two diabetic foot ulcer classification systems: the Wagner and the University of Texas wound classification systems. Diabetes Care 24: 84–8
Piaggesi A, Macchiarini S, Rizzo et al (2007) An off-the-shelf instant contact casting device for the management of diabetic foot ulcers: a randomized prospective trial versus traditional fiberglass cast. Diabetes Care 30: 586–90
Sarnow MR, Veves A, Giurini JM et al (1994) In-shoe foot pressure measurements in diabetic patients with at-risk feet and in healthy subjects. Diabetes Care 17: 1002–6
Young CR (1993) The F-Scan system of foot pressure analysis. Clin Podiatr Med Surg 10: 455–61

Related content
Is artificial intelligence the key to better foot self-care in diabetes?
;
Free for all UK & Ireland healthcare professionals

Sign up to all DiabetesontheNet journals

 

By clicking ‘Subscribe’, you are agreeing that DiabetesontheNet.com are able to email you periodic newsletters. You may unsubscribe from these at any time. Your info is safe with us and we will never sell or trade your details. For information please review our Privacy Policy.

Are you a healthcare professional? This website is for healthcare professionals only. To continue, please confirm that you are a healthcare professional below.

We use cookies responsibly to ensure that we give you the best experience on our website. If you continue without changing your browser settings, we’ll assume that you are happy to receive all cookies on this website. Read about how we use cookies.