This site is intended for healthcare professionals only

Continuous glucose monitoring in children with type 1 diabetes

Rhonda Bleakly

Continuous glucose monitoring (CGM) can help people with diabetes to optimise their glycaemic control. Changes in treatment guided by the information obtained from CGM can result in improved HbA1c levels and reduced risk of hypoglycaemia. In addition, CGM can be an educational and motivating tool if used appropriately with adequate support from healthcare professionals. In this article, the author carries out a literature review of studies on the use of CGM among children with type 1 diabetes and discusses the potential benefit of CGM in this population.

Type 1 diabetes is one of the most common chronic childhood illnesses affecting one in 550 children in the UK (Department of Health and Department for Education and Skills, 2005). The main goals of diabetes care include good metabolic control, minimisation of complications and maintaining a good quality of life (QOL). Failure to achieve these goals results not only in poor QOL for the person with diabetes, but is a huge strain on the health service, with the treatment of diabetes costing an estimated £5 million per day (Williams and Pickup, 2004). Much of this cost is attibutable to complications, which can be reduced with good professional care and self-management (Department of Health and Diabetes UK, 2005).

The introduction of continuous glucose monitoring (CGM) as a form of blood glucose monitoring has the potential to help people with diabetes achieve target HbA1c levels while reducing the risk of severe hypoglycaemia. Although CGM has been in clinical use for approximately 12 years, the evidence surrounding its superiority over traditional blood glucose monitoring remains controversial. In this article, the author discusses the potential benefits of using CGM in children with type 1 diabetes.

Background
Despite the benefits of intensive insulin regimens, the potential benefits of new insulins and methods of delivery for overall metabolic control in children and adolescents has improved little in the UK in the past decade. For example, only 20% of children and young people with type 1 diabetes in Northern Ireland meet the recommended HbA1c target of <7.5% (<58 mmol/mol; Cardwell et al, 2005). Furthermore, the fourth National Diabetes Audit has shown that paediatric care currently does not meet nationally agreed standards and will continue to cause health problems for young people with diabetes both now and in the future (Edge et al, 2005). Tight glycaemic control in people with type 1 diabetes is essential for delaying the progression of microvascular disease and improving long-term outcomes (DCCT [Diabetes Control and Complications Trial] Research Group, 1993). 

Glycaemic control is even more challenging among children who have varying levels of activity and erratic eating patterns, leading to a great degree of blood glucose fluctuation. In recent years, the use of rapid and long-acting insulin analogues, improvements in insulin pump technology and increased frequency of blood glucose monitoring have gone some way in helping to achieve target HbA1c levels in people with type 1 diabetes. However, the maintenance of euglycaemia with intensive insulin therapy is limited by the increased risk of hypoglycaemia. Fear of hypoglycaemia may lead to increased anxiety, non-adherence or under-dosing of insulin, resulting in poor glycaemic control (McAulay et al 2001; Davis and Alonso, 2004; Álvarez Guisasola et al, 2008; Labad et al, 2010). Even the most intense monitoring of blood glucose levels gives only a glimpse of the fuller picture and does not give information about glucose levels overnight.

Lock et al (2002) suggest that glycaemic control can be maintained through regular self-monitoring of blood glucose (SMBG) and appropriate action, to help prevent long-term complications. However, in addition to the discomfort associated, traditional finger-stick testing is limited by the fact that the readings simply represent distinct points in time. As individuals typically test no more than three or four times per day and generally do not test overnight, frequent glucose peaks and asymptomatic hypoglycaemia can be undetected leading to poor glucose control (Kaufman et al, 2002). Lack of information regarding trends in the glucose profile limit accurate adjustments of insulin therapy. 

CGM is capable of detecting unrecognised hypoglycaemia and other blood glucose patterns that are undetectable through conventional glucose monitoring. The CGM sensor is inserted subcutaneously by a healthcare professional. Interstitial glucose measurements are recorded every 5 minutes for 72 hours, giving up to 288 daily glucose readings. There is a good correlation between interstitial glucose and plasma glucose levels (Sachedina and Pickup, 2003); however, results may not be accurate during rapidly changing blood glucose levels (Monsod et al, 2002). Calibration with capillary blood glucose levels is required during CGM use, requiring four finger-stick measurements per day. The individual is also asked to keep a food, insulin and event diary while wearing the CGM sensor. The downloaded glucose data are displayed in graph format and analysed to assist the individual in making optimal treatment decisions (Klonoff, 2005).

Literature review
A literature review was carried out using databases including MEDLINE and ProQuest. The search terms “continuous glucose monitoring”, “children” and “type 1 diabetes” were used. Several key studies examining the benefits of CGM in both children and adults with type 1 diabetes were identified. These are summarised in Table 1. 

Chase et al (2001) demonstrated marked increases in plasma glucose levels after meals, even in children with low HbA1c levels. By viewing continuous data and trend graphs, people with diabetes can react to high or low blood glucose levels before they become dangerous. In addition, this information can provide insights into the underlying causes of glucose fluctuations, allowing further adjustments to insulin therapy to be made by healthcare professionals.

For CGM to be accepted for widespread use, the devices must be comfortable to wear, easy to operate and provide accurate results. There are generally two types of CGM: one that records data to be analysed retrospectively and one that gives real-time glycaemic values. 

Chase et al (2001) and Kaufman et al (2002) were the first to report the use of CGM in children. Both studies demonstrated a significant improvement in HbA1c levels in children using CGM for relatively short periods (30 days and 3 months, respectively). Similarly, Ludvigsson and Hanas (2003) reported that there were significant improvements in HbA1c levels among the paediatric group studied (n=27) over a 12-week period (see Table 1). CGM was used for 3 days every 2 weeks over the 3-month period, leading to an improved mean HbA1c level from 7.70% (61 mmol/mol) to 7.31% (56.1 mmol/mol). Deiss et al (2004) studied 50 children transferring to insulin pump therapy (continuous subcutaneous insulin infusion [CSII]) and demonstrated improvements in glycaemic control when using CGM (see Table 1). The most marked improvement was among those who had poor glycaemic control (HbA1c level >8% [>64 mmol/mol]) prior to starting CSII. A randomised controlled trial (RCT) with CGM was performed by a European study consortium (Deiss et al, 2006) (see Table 1). Among the participants, 50% were children (n=81) and the study demonstrated significant reductions in HbA1c level after 1 and 3 months of use. 

The results of a 6-month trial by Lagarde et al (2006) (see Table 1) suggest CGM improves metabolic control and are consistent with previous studies. The study also examined whether improvements in HbA1c levels occurred at the expense of frequent episodes of hypoglycaemia. There were no significant differences between the frequencies of hypoglycaemia reported in the intervention and control groups. Therefore, improvements in HbA1c levels were achieved without increasing risk of hypoglycaemia. However, it has been noted that CGM may be inaccurate during periods of hypoglycaemia (Monsod et al, 2002). 

The results of an independent study carried out by the Juvenile Diabetes Research Foundation (JDRF) CGM Study Group et al (2008) contradict the reported positive results of earlier, smaller studies (see Table 1). This large study examined whether CGM can help people with type 1 diabetes to manage their condition. The RCT took place across 10 sites in the USA and involved people with type 1 diabetes aged 8–72 years (n=322). Participants were divided into three age bands (8–14, 15–24 and 25 years), with each age group being randomised to use a CGM device or to record information from standard finger-stick blood testing. The groups were followed for 26 weeks and changes in HbA1c levels were used to assess the effectiveness of the different monitoring methods. At the commencement of the study, each participant had an HbA1c level of 7–10% (53–86 mmol/mol). NICE (2004) guidelines recommend a target HbA1c level of <7.5% (<58 mmol/mol) for adults and children. 

The study showed that the benefits associated with CGM was strongly related to age (JDRF CGM Study Group et al, 2008). The group aged ≥25 years had improvements in all measures of glycaemic control, including a ≥10% relative reduction of the mean HbA1c level compared with baseline. In contrast, the groups aged 8–14 and 15–24 years did not achieve statistically significant reductions in HbA1c levels. The results of the study indicate that CGM improves HbA1c levels in people with type 1 diabetes aged ≥25 years who have the necessary motivation to use the technology, as supported by Montagnana et al (2009). In contrast to findings previously reported by the DCCT Research Group (1993), which showed that improved control resulted in a three-fold increase in the frequency of severe hypoglycaemic episodes, JDRF reported fewer episodes of hypoglycaemia with improved glycaemic control (JDRF CGM Study Group et al, 2008).

The participants in the studies were generally those who were motivated and had good HbA1c levels at baseline. Therefore, it is not possible to generalise the results to include the less-motivated individual. Individuals who had most significant improvements in glycaemic control were those who had more consistent use of the sensors. Subsequent follow-up of this study for 12 months demonstrated that improvements in glycaemic control were maintained in those who continued to use the sensor (Bode et al, 2009). 

Psychological issues
Clinical use of CGM devices could have a significant impact on family management of paediatric diabetes. To date, psychological research on its use is limited. Only a few of the studies have used QOL as a measure of effectiveness and often this may be an important reason for people to use CGM in addition to their usual self-monitoring.

Reported results are inconclusive stating that CGM could potentially produce beneficial or adverse psychological reactions (Diabetes Research in Children Network Study Group, 2006). In addition to glycaemic benefits, CGM may help to encourage, motivate and empower people to take control of their diabetes. It has the potential to reinforce concepts that are taught in diabetes education and to reduce the fear of hypoglycaemia.

For some, the extra information obtained may cause additional stress. Such people may find it difficult to understand and feel burdened with the extra knowledge, while others may be naturally apprehensive about the invasiveness of the procedure. The procedure should be carefully explained by an appropriately trained and competent healthcare professional. The diabetes team must then be able to interpret the recorded data and make informed decisions to assist the individual to maximise their glycaemic control. Hammond et al (2010) state that the key to effective use of CGM is interpretation of the data.

It is important not to give people unrealistic expectations about CGM as some may believe that it could replace the need to carry out blood glucose measurements. A study by Ritholz (2008) found that those with high HbA1c levels expected CGM to improve glycaemic control. In contrast, those with lower HbA1c level understood that they themselves needed to work with the data consistently in order to make changes. A careful patient selection process is required, and as CGM is still a relatively new addition to the local service, a care pathway would be a useful tool to develop. 

Limitations
The studies discussed above raise the question as to how frequently CGM needs to be used to achieve the desired outcome. The findings from a randomised study by Hirsch et al (2008) indicate that the more often people use CGM, the better glycaemic control they can achieve without the risk of hypoglycaemia (see Table 1). 

A difficulty in comparing these studies was that each study used CGM for a different lengths of time and at various intervals. It is apparent that one 3-day period of CGM is probably insufficient to translate into any meaningful improvement in diabetes control. There may even be a tendency for the adolescent to change behaviour during sensor use; therefore, giving inconsistent CGM information for the 3-day period. 

The fact that CGM data are retrospective can also be regarded as a limitation of the studies. The numbers and age groups of participants also varied greatly between studies, which were all short-term. The reduction in HbA1c levels in children’s studies may be attributable to parental input in adjustment of therapy. Further RCTs for extended time periods are needed to provide evidence of the benefits of CGM among children.

Conclusion
Type 1 diabetes in children and adolescents is characterised by variable blood glucose control, tendency to experience hypoglycaemia and difficulties in insulin adjustment. The need to protect this group against the long-term consequences of hypoglycaemia and hyperglycaemia is vital. The availability of CGM is a significant advance that has the potential to assist diabetes care for those with poor metabolic control and those with suspected nocturnal hypoglycaemia. This review of the literature has demonstrated positive outcomes in glycaemia while using CGM, although the sample sizes of the studies have been small. In contrast to insulin adjustments made on SMBG alone, CGM-guided adjustments can improve glycaemia without increased risk of hypoglycaemia (Lagarde et al, 2006). Box 1 gives an example of how CGM data can be used to improve glycaemic control.

Although some people may have an unrealistic expectation of CGM – anticipating that it will improve their glycaemic control instantly – others realise the commitment and work required to sustain significant improvements. Careful patient selection is required as the success of CGM depends on the individual and family understanding and willingness to change behaviour based on the CGM results.

Even small changes in HbA1c levels driven by an increase in patient knowledge and motivation may have long-term benefits. The key to effective use of CGM is interpretation of the data, support from the healthcare team and realistic expectations from the individual and the family, ultimately empowering the child and family to understand their glucose patterns and maximise their diabetes management.

REFERENCES:

Álvarez Guisasola F, Tofé Povedano S, Krishnarajah G et al (2008) Hypoglycaemic symptoms, treatment satisfaction, adherence and their associations with glycaemic goal in patients with type 2 diabetes mellitus: findings from the Real-Life Effectiveness and Care Patterns of Diabetes Management (RECAP-DM) Study. Diabetes Obes Metab 10(Suppl 1): 25–32 
Bode B, Xing D; Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) Sustained benefits of continuous glucose monitoring through 12 months of sensor use in the JDRF CGM randomised clinical trial. Diabetes 58(Suppl 1): 204
Cardwell CR Patterson CC Allen M et al (2005) Diabetes care provision and glycaemic control in Northern Ireland: a UK regional audit. Arch Dis Child 90: 468–73
Chase PH, Kim LM, Owen SL et al (2001) Continuous subcutaneous glucose monitoring in children with type 1 diabetes. Pediatrics 107: 222–6
Davis S, Alonso MD (2004) Hypoglycemia as a barrier to glycemic control. J Diabetes Complications 18: 60–8
Deiss D, Hartman R, Hoeffe J, Kordonouri O (2004) Assessment of glycemic control by continuous glucose monitoring system in 50 children with type 1 diabetes starting on insulin pump therapy. Pediatr Diabetes 5: 117–21
Deiss D, Bolinder J, Riveline JP et al (2006) Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 29: 2730–2
Department of Health and Department for Education and Skills (2005) Managing Medicine in Schools and Early Years Settings. DH, London. Available at: http://bit.ly/iuarxC (accessed 14.06.11)
Department of Health and Diabetes UK (2005) Structured Patient Education in Diabetes: Report from the Patient Education Working Group. DH, London. Available at: http://bit.ly/d2U9DW (accessed 14.06.11)
Diabetes Control and Complications Trial (DCCT) Research Group (1993) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329: 977–86
Diabetes Research in Children Network (DirecNet) Study Group (2006) Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes. Pediatr Diabetes 7: 32–8
Edge JA, Swift PG, Anderson W et al (2005) Diabetes services in the UK: fourth national survey; are we meeting NSF standards and NICE guidelines? Arch Dis Child 90: 1005–9
Hammond PJ, Amiel SA, Dayan CM et al (2010) ABCD position statement on continuous glucose monitoring: use of glucose sensing in outpatient clinical diabetes care. Practical Diabetes International 27: 66–8
Hirsch IB, Abelseth J, Bode BW et al (2008) Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther 10: 377–83
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group; Tamborlane WV, Beck RW, Bode BW et al (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359: 1464–76
Kaufman FR, Austin J, Neinstein A et al (2002) Nocturnal hypoglycemia detected with the continuous glucose monitoring system in pediatric patients with type 1 diabetes. J Pediatr 141: 625–30
Klonoff DC (2005) Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care 28: 1231–9
Labad J, Price JF, Strachan MW et al (2010) Symptoms of depression but not anxiety are associated with central obesity and cardiovascular disease in people with type 2 diabetes: the Edinburgh Type 2 Diabetes Study. Diabetologia 53: 467–71
Lagarde WH, Barrows FP, Davenport ML et al (2006) Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr Diabetes 7: 159–64
Lock JP, Szuts EZ, Malomo KJ, Anagnostopoulos A (2002) Whole-blood glucose testing at alternate sites: glucose values and hematocrit of capillary blood drawn from fingertip and forearm. Diabetes Care 25: 337–41
Ludvigsson J, Hanas R (2003) Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 111: 933–8
McAulay V, Deary IJ, Frier BM (2001) Symptoms of hypoglycaemia in people with diabetes. Diabet Med 18: 690–705
Monsod TP, Flanagan DE, Rife F et al (2002) Do sensor glucose levels accurately predict plasma glucose concentrations during hypoglycemia and hyperinsulinemia? Diabetes Care 25: 889–93
Montagnana M, Lippi G, Guidi GC (2009) Continuous glucose monitoring and type 1 diabetes N Engl J Med 360: 190
NICE (2004) Type 1 Diabetes: Diagnosis and Management of Type 1 Diabetes in Children, Young People and Adults. NICE, London. Available at: http://bit.ly/gNUHei (accessed 14.06.11)
Ritholz M (2008) Is continuous glucose monitoring for everyone? Consideration of psychosocial factors. Diabetes Spectr 21: 287–9
Sachedina N, Pickup JC (2003) Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in type 1 diabetic subjects. Diabet Med 20: 1012–15
Williams G, Pickup JC (2004) Handbook of Diabetes. 3rd edn. Wiley–Blackwell Publishing, London 

Related content
The GIRFT return on investment tool and the role of diabetes inpatient specialist nurses
;
Free for all UK & Ireland healthcare professionals

Sign up to all DiabetesontheNet journals

 

By clicking ‘Subscribe’, you are agreeing that DiabetesontheNet.com are able to email you periodic newsletters. You may unsubscribe from these at any time. Your info is safe with us and we will never sell or trade your details. For information please review our Privacy Policy.

Are you a healthcare professional? This website is for healthcare professionals only. To continue, please confirm that you are a healthcare professional below.

We use cookies responsibly to ensure that we give you the best experience on our website. If you continue without changing your browser settings, we’ll assume that you are happy to receive all cookies on this website. Read about how we use cookies.